GOVERNMENT BUILDINGS >>> WATER AND DEFECTS- liquid/ water and building envelope |
Hospital Building |
Bungalow/House |
Student Housing |
Apartment/Flat |
Office |
Airport Arrival Hall |
Parking Floor/ Building |
Public Function Hall |
University Buildings |
Laboratory/Testing Building |
Weapon Storage |
Airport Hanger |
Police Buildings |
School Buildings |
Mosque |
TNB Sub-station |
BOMBA buildings |
Switch Rooms |
Training Centre |
Sports Hall |
Court House |
MAIN TOTAL |
Moisture/ Thermal vapour |
7 |
1 |
0 |
2 |
23 |
3 |
4 |
3 |
11 |
3 |
2 |
0 |
8 |
7 |
1 |
0 |
3 |
0 |
3 |
2 |
3 |
86 |
Damp- proofing/ rising-lift pit |
8 |
2 |
1 |
4 |
18 |
0 |
8 |
5 |
5 |
4 |
4 |
2 |
3 |
13 |
6 |
0 |
4 |
0 |
4 |
4 |
1 |
96 |
Wall/Floor slab-crack/ leak and seepage |
21 |
7 |
21 |
11 |
27 |
4 |
9 |
3 |
9 |
4 |
4 |
4 |
11 |
21 |
4 |
11 |
6 |
7 |
5 |
3 |
3 |
195 |
Material deterioration |
9 |
7 |
8 |
9 |
12 |
12 |
13 |
4 |
9 |
6 |
4 |
3 |
14 |
17 |
4 |
6 |
7 |
4 |
3 |
5 |
4 |
160 |
Materials corrosion |
3 |
5 |
6 |
6 |
9 |
9 |
8 |
3 |
6 |
5 |
2 |
1 |
7 |
7 |
3 |
3 |
3 |
1 |
1 |
3 |
2 |
93 |
Poor construction details- floor, wall ceiling |
8 |
12 |
22 |
11 |
23 |
12 |
11 |
7 |
21 |
7 |
5 |
5 |
21 |
23 |
6 |
4 |
5 |
4 |
6 |
5 |
4 |
222 |
Internal wet areas- no waterproofing, cracks etc |
24 |
12 |
21 |
20 |
26 |
5 |
0 |
3 |
21 |
3 |
0 |
0 |
22 |
24 |
6 |
0 |
5 |
0 |
4 |
5 |
6 |
207 |
Flat concrete roof problems |
25 |
12 |
21 |
31 |
30 |
7 |
9 |
4 |
23 |
6 |
4 |
4 |
26 |
23 |
9 |
17 |
11 |
7 |
5 |
4 |
4 |
282 |
Skylight leak/ sealant defects |
12 |
3 |
5 |
4 |
21 |
11 |
0 |
0 |
8 |
2 |
0 |
.3 |
4 |
5 |
3 |
0 |
1 |
0 |
3 |
2 |
3 |
90 |
Roof with swimming/ other pools leakage |
0 |
5 |
0 |
11 |
5 |
0 |
0 |
0 |
6 |
0 |
0 |
0 |
5 |
4 |
|
0 |
1 |
0 |
0 |
0 |
0 |
37 |
Leak through door frame |
13 |
11 |
14 |
12 |
16 |
8 |
0 |
4 |
11 |
3 |
1 |
0 |
21 |
22 |
7 |
0 |
2 |
0 |
4 |
4 |
1 |
154 |
Leak through window frame/ expired sealant |
23 |
22 |
31 |
33 |
39 |
0 |
0 |
3 |
21 |
4 |
0 |
0 |
22 |
21 |
7 |
0 |
2 |
0 |
4 |
4 |
1 |
154 |
Air cond. piping leak |
23 |
22 |
31 |
33 |
39 |
0 |
0 |
3 |
21 |
4 |
0 |
0 |
22 |
21 |
8 |
0 |
6 |
0 |
4 |
4 |
1 |
154 |
Water piping leak |
20 |
11 |
19 |
21 |
32 |
0 |
0 |
4 |
23 |
3 |
0 |
0 |
33 |
21 |
7 |
0 |
2 |
0 |
4 |
4 |
1 |
154 |
Gutter leak |
19 |
13 |
21 |
20 |
28 |
4 |
4 |
3 |
32 |
2 |
0 |
3 |
23 |
20 |
4 |
0 |
4 |
0 |
3 |
3 |
2 |
208 |
RWDP problems |
21 |
18 |
21 |
26 |
32 |
4 |
3 |
2 |
31 |
3 |
3 |
1 |
31 |
25 |
8 |
0 |
4 |
1 |
2 |
2 |
2 |
240 |
Leakage from water tank |
9 |
12 |
23 |
27 |
32 |
0 |
0 |
1 |
22 |
3 |
0 |
0 |
21 |
19 |
0 |
0 |
1 |
0 |
1 |
1 |
1 |
173 |
Structure repair/ spalling |
12 |
11 |
21 |
20 |
23 |
0 |
7 |
1 |
19 |
1 |
3 |
0 |
11 |
15 |
3 |
2 |
2 |
1 |
1 |
1 |
1 |
155 |
Balcony/ planters box leak |
7 |
6 |
8 |
11 |
10 |
4 |
5 |
2 |
11 |
1 |
0 |
0 |
12 |
11 |
3 |
0 |
1 |
0 |
2 |
2 |
2 |
98 |
MAIN TOTAL |
253 |
179 |
275 |
300 |
429 |
85 |
81 |
56 |
311 |
64 |
34 |
27 |
316 |
321 |
86 |
47 |
75 |
30 |
59 |
56 |
47 |
3131 |