The Effects Of Night-Time Simulation Using Vertical Greenery System In High-Rise Building
Table 1: Ground Level VGS Thermal Performance
Time / Mean | Amb. Temp.Control°C | Amb. Temp.VGS°C | Indoor DBTControl°C | Indoor DBT VGS°C | Avg. Temp. Reduction°C |
Mean/Avg | 27.26 | 27.26 | 31.32 | 30.87 | 0.45 |
Mean Max | 31.5 | 31.5 | 32.84 | 32.2 | |
Mean Min | 23.8 | 23.8 | 29.87 | 29.52 |